

Table 2 lists each 3-phase constant for the respective 3-phase voltage obtained from the above calculation. The two-leg inverter converts this Dc link voltage into 3 phase supply. They can also provide split phase voltages from the three phase power source. Now, if you look at the “1,000 ÷ 1.732V” portion of this equation, you can see that by inserting the respective 3-phase voltage for “V” and multiplying it by 1.732, you can then divide that resulting quantity into “1,000” to get a specific number (or constant) you can use to multiply “kW” to get the current draw of that 3-phase load at the respective 3-phase voltage. Phase converters operate by converting single phase power into three phase power. If you have a piece of equipment that draws 80A, then you can calculate the relative size of the required power source, which is 10kW (80 ÷ 8.33).īy using this same procedure but inserting the respective single-phase voltage, you get the following single-phase constants, as shown in Table 1.įor 3-phase systems, we use the following equation:Īgain, assuming unity PF and solving this equation for “I,” you get: So, if you have a 10kW load, you can calculate the current draw to be 83.3A (10 × 8.33). Single Phase to 3 Phase Converter, MY-PS-15 Model, Suitable for 10HP(7.5Kw) 30 Amps 200-240V 3 Phase Motor, DPS Should Be Used for One Motor Only, Input/Output 200V-240V, Digital Type.

Now, if we look at the “1,000 ÷ V” portion of this equation, you can see that by inserting the respective single-phase voltage for “V” and dividing it into the “1,000,” you get a specific number (or constant) you can use to multiply “kW” to get the current draw of that load at the respective voltage.įor example, the constant for the 120V calculation is 8.33 (1,000 ÷ 120). Single-Phase Calculationsīasic electrical theory tells us that for a single-phase system,įor the sake of simplicity, let's assume the power factor (PF) is unity. The Control subsystem implements the cycloconverter RMS voltage control. So he thought that a 3 phase converter would work. You can use constants that apply to specific single- and 3-phase voltages to calculate current (I) and kilowatts (kW). The cycloconverter consists of 36 thyristors and has the capacity to lower the frequency of the input voltage. I have a customer who is in a rural area and 3 Phase power was not a viable option(50000+). Phase converters provide three-phase power from single-phase lines at a fraction of the installation and operating cost of running three-phase utility lines. No matter what the circumference and diameter of the respective circle, their ratio is always pi. You may ask, “What exactly is a constant?” An example of a constant with which you're very much familiar is pi (π), which is derived by dividing a circle's circumference by its diameter. We'll also show you how you can do these calculations “in your head,” with very reasonable accuracy, through the use of constants. This month, we'll discuss the most fundamental of calculations - those for current (I) and kilowatts (kW). Then, the main power component voltage and current stresses are determined and simulation results in PLECS are provided. High power converters are important building blocks for future electric mobility and. Many solutions exist such as static phase. Three-Phase High-Power Converter Design and Analysis Workflow.
#3 phase power converter series
Technical help is readily available if needed.Welcome to the first in a series of articles focusing on electrical calculation basics. Three phase power is scarce in many parts of rural America, but the need for three phase motor control is real.
#3 phase power converter full
Guaranteed long-term performance is our promise to every customer.Ī 2 year warranty is supplied along with a full stock of replacement parts. Single Phase to 3 Phase Converter, My-PS-3 Model, Suitable for 2HP (1. Typical application in operating 1-150 HP, 3-phase motors to their maximum capacity include:ĭyna-Phase rotary converters have been in operation for over 35 years. Manufacturing's extensive range of high quality Dyna-Phase rotary phase converter units provide a reliable 3-phase power solution to your single phase service problem. Take advantage of the many benefits of adapting your single phase power service to versatile 3-phase power, without the high cost of installing a 3-phase service. This research aimed to design a three-phase ac-dc buck converter to achieve low-THD unity-power-factor sinusoidal input current and regulated dc voltage via modified pulse-width-modulation. Ecoonomical, High Performance 3-Phase Power
